COURSES
THEORETICAL AND PRACTICAL
We offer theoretical and practical courses for engineers and electrical technicians on electrical concepts and testing.
SERVICE OF
LABORATORY
We have a complete laboratory for calibration and repair of test instruments with which we provide after-sales support.
METERTEST
STATIONARY LABORATORY EQUIPMENT
ASTeL 3.2X-XX Test Stand for Three-Phase Meters
- Fully automated procedures
- Automatic meter adjustments - Accuracy energy standards 0.01, 0.02, 0.04, 0.05
- Wide voltage range up to 480 V and currents up to 240 A
- Independent operation of voltage and current signals
- Harmonic generation up to the 41st harmonic.
- Wide range of safety functions
- Number of customizable positions
- Simultaneous testing of different meter constants
- Windows® based control software
- Customizable functions and special features
Meter Sampling Equipment
TECHNICAL CHARACTERISTICS:
| ASTeL model | 3.24(H) (1) | 3.22(H) (1) | 3.21(H) (1) | |
| Number of phases | Three-phase | |||
| Accuracy | @ PF=1 | ±0.02% | ±0.01% | ±0.005% |
| @ PF≥0.5 | ±0.04% | ±0.02% | ±0.01% | |
| Source | Type | PS3(H) (1) | ||
| Voltage source | 400VA, 1200VA, 2600VA | |||
| Operating voltage range | 3 x 30 ... 350 (480) V (Phase-Neutral) (2) | |||
| Current source | 600VA, 1600VA, 2400VA, 3000VA, 3600VA | |||
| Current operating range | 3 x 1mA ... 120 (240) A (2) | |||
| Frequency | 40 ... 70Hz (3) | |||
| Harmonic standard version | up to 21, user programmable | |||
| Harmonic version H | up to 41, user programmable (4) | |||
| Reference pattern | RD-30 | RD-31 | RD-33 | |
| Frame | Type | SR-3 | ||
| Number of positions | 1 ... 60 (according to the user's request) | |||
| Separation I-P | Current Separating Transformer CTS | |||
| Software | AsTest for Windows | |||
| Accessories | Optional OPTO readout port, HHT terminal | |||
(1) Version (H) is available, e.g. ASTeL 1.24(H) means that ASTeL 1.24 and ASTeL 3.24H are available.
(2) Other values available upon request.
(3) Operating range. Specified range 45 to 65 Hz.
(4) According to Chinese standard JJG 597-2005.
ASTeL 1.2X-XX Test Stand for Single Phase Meters
- Automatic meter settings
- Accuracy energy standards 0.01, 0.02, 0.04, 0.05
- Wide voltage range up to 480 V and currents up to 240 A
- Independent operation of voltage and current signals
- Harmonic generation up to 41
- Wide range of safety functions
- Number of customizable positions
- Simultaneous testing of different meter constants
- Windows® based control software
- Customizable functions and special features
Meter Test Equipment
TECHNICAL CHARACTERISTICS:
ASTeL Model | 1.24(H) (1) | 1.22(H) (1) | 1.21(H) (1) | |
Number of phases | Single-phase | |||
Accuracy | @ PF=1 | ±0.02% | ±0.01% | ±0.005% |
@ PF≥0.5 | ±0.04% | ±0.02% | ±0.01% | |
Source | Type | PS1(H) (1) | ||
Voltage source | 400VA, 1200VA, 2600VA | |||
Operating voltage range | 1 x 30 ... 350 (480) V (phase-Neutral) (2) | |||
Current source | 600VA, 1600VA, 2400VA, 3000VA, 3600VA | |||
Current operating range | 1 x 1 mA ... 120 (240) A (2) | |||
Frequency | 40 ... 70Hz (3) | |||
Harmonic standard version | up to 21ouser programmable | |||
Harmonic version H | up to the 41stuser programmable (4) | |||
Reference pattern | RD-20 | RD-21 | RD-23 | |
Frame | Type | SR-1 | ||
Number of positions | 1 ... 80 (according to user's request) | |||
Separation I-P | MSVT multisecondary voltage isolating transformer | |||
Software | AsTest for Windows | |||
Accessories | Optional OPTO readout port, HHT terminal | |||
(1) Version (H) is available, e.g. ASTeL 3.24(H) means that ASTeL 3.24 and ASTeL 3.24H are available.
(2) Other values available upon request.
(3) Operating range. Specified range 45 to 65 Hz.
(4) According to Chinese standard JJG 597-2005.