OUR
ALLIES
COURSES
THEORETICAL AND PRACTICAL
We offer theoretical and practical courses for engineers and electrical technicians on electrical concepts and testing.
SERVICE OF
LABORATORY
We have a complete laboratory for calibration and repair of test instruments with which we provide after-sales support.
Isolation Monitoring ISOMETER
ISO series (ISO685-.., ISO685-...-B, ISO685-...-):
Isolation monitors for main current circuits in IT systems, with components directly connected to current converters, rectifiers. UPS installations, battery networks.
IR series (IR420-D4, IR125Y-4, IR425):
Isolation monitors for control circuits in IT systems (Generating Plants, Substations, Mobile Generators).
IR Series (IR470LY, IR470LY2-4061):
Isolation monitors for main current circuits in IT systems, (Motors, Pumps) - without directly connected rectifiers.
ISOPV series (ISOPV, ISOPV425):
Isolation monitors for AC, AC/DC and DC power supplies in IT isolated systems, for solar systems with large capacities up to 2000 µf, solar systems with directly connected inverters, solar systems with high but slow voltage fluctuations, systems with switched-mode power supplies. AC systems up to 793V or 690V. DC systems up to 1100V or 1000V.
IRDH Series (IRDH275BM-7):
Isolation monitors in IT isolated systems, for AC/DC medium voltage main current circuits with directly connected current components such as current rectifiers, converters, thyristor-controlled DC drives, etc.
ISORW series (ISORW685W-D):
Isolation monitors for IT systems for AC, AC/DC and DC main and control circuits in railway applications (train system, Metro).
ISOSCAN Troubleshooting System:
EDS series (EDS 460/490, EDS 461/491):
Troubleshooting system in IT systems, in main circuits and control circuits in Industrial Installations, Power Plants, Offshore Platforms, Food Industry.
EDS Series (EDS309...):
Portable IT system troubleshooting system for main and control circuits in Industrial Installations, Power Plants, Offshore Platforms, Food Industry.
Differential Current Monitoring
RCM/RCMA Series:
Type B residual current monitors for AC/DC monitoring (0...2000 Hz) with analog output.
RCMS Series:
For monitoring fault, load, neutral or ground currents at up to 1080 points in max. 200 ms.
PRODUCTS / Bender
DISPOSITIVOS DE VIGILANCIA DE AISLAMIENTO
Monitorean la resistencia de aislamiento en sistemas IT, previniendo fallos eléctricos y garantizando la seguridad en instalaciones críticas.
SISTEMAS DE LOCALIZACIÓN DE FALLOS DE AISLAMIENTO
Detectan automáticamente fallos de aislamiento en sistemas IT, facilitando el mantenimiento y reduciendo tiempos de inactividad.
LOCALIZADORES PORTÁTILES DE FALLOS DE AISLAMIENTO
Equipos móviles que identifican fallos de aislamiento en sistemas IT, ideales para mantenimiento en campo y diagnóstico rápido.
MONITORES DE CORRIENTE DIFERENCIAL RESIDUAL
Supervisan corrientes de fuga en sistemas eléctricos, previniendo riesgos y garantizando la continuidad operativa.
MONITORES DE RESISTENCIA DE PUESTA A TIERRA (NGRM)
Vigilan la resistencia de puesta a tierra en sistemas con neutro conectado a tierra, asegurando la integridad del sistema.
RELÉS DE MEDIDA Y VIGILANCIA
Dispositivos que supervisan parámetros eléctricos clave, protegiendo equipos y garantizando operaciones seguras.
CONTROLADORES DE CARGA
Gestionan la distribución de carga eléctrica, optimizando el consumo y mejorando la eficiencia energética.
TRANSFORMADORES TOROIDALES
Detectan corrientes de fuga mediante la medición de corriente diferencial, esenciales para la protección eléctrica.
CONTACT US
Contact our team for more information about our products. Bender.
Luis Agudelo
Sp. in Project Management
National University of Colombia
Director de Líneas BENDER
(+57) 6014864030
Ext: 1121





































