High Voltage Equipment

¿Por qué usar seccionadores de HAPAM?

  • Mas de 75 años de experiencia
  • Diseño durable y fiable
  • Mas de 30.000 seccionadores y cuchillas de puesta a tierra Actualmente en servicio en mas de 80 paises   de todo el mundo
  • Virtualmente libre de mantenimiento.

Cuchilla principal

La cuchilla principal está fabricada con un tubo de aluminio y contactos de cobre cubiertos con plata en ambos extremos. Durante el cierre del seccionador, la cuchilla principal efectúa un doble movimiento: primero, la cuchilla principal desciende hasta que alcanza una posición completamente horizontal y entonces gira de modo que la presión de contacto se aplica en ambos extremos del seccionador.

Los contactos principales son de diseño “ lazo invertido “ lo cual los hace adecuados para corrientes de cortocircuito muy elevadas. se proveen pantallas anti-corona.

Cuchillas de puesta a tierra

Los seccionadores Hapam pueden ser equipados con cuchillas de puesta a tierra, instaladas al lado derecho y/o izquierdo.

La cuchilla de puesta a tierra consiste de un tubo de aluminio, provisto con contactos recubiertos de plata en ambos extremos.

La cuchilla de puesta a tierra consiste de un tubo de aluminio, provisto con contactos recubiertos de plata en ambos extremos.

Tipos de seccionadores:

  • Seccionador de apertura central SSBII
  • Seccionador de doble apertura SSBIII
  • Seccionador de apertura Vertical VSSBIII
  • Seccionador Semipantografo VKSBIII
  • Seccionador Pantografo GSSB
  • Cuchillas de puesta a tierra Tipo TEB

Current and Potential Transformers

Current Transformers for Outdoor Use

Current transformers are used in high-voltage networks in the range of 24 -550 kV. They transform high currents to standardized values for meters and protection and measuring devices.

Technical Characteristics:

  • Paper-Oil and SF6 Gas Insulation.
  • From 24 to 550 kV.
  • Minimal oil volume, high grade mineral oil and PCB-free.Instrument transformers (CT/PT)
  • The active part is located in the transformer head enclosure.
  • Fine graduation nozzle.
  • Stainless steel expansion bellows
  • Ratio change through primary (optional Secondary).
  • Housing explosion tested.
  • Precise control of the electric field and prevention of local partial discharges through the fine graduated nozzle.
  • Increased safety by preventing subsequent arching formation.
  • High operational safety, as there are no live parts in the isolator.

Type

  • JOF T (24 -123) kV Outdoor Use, insulated in Paper - Oil
  • JOF (24 - 550) kV Outdoor Use, insulated in Paper - Oil
  • JGF (245 - 550) kV Outdoor use, insulated in SF6 Gas

More information: www.pfiffner-group.com

Inductive Voltage Transformers for Outdoor Use:

Voltage transformers are used in high-voltage networks in the range 24 - 550 kV. They transform high voltage into standardized values for meters and protection and measuring devices.

Technical Characteristics:

  • Paper-Oil and SF6 Gas Insulation.
  • From 24 to 550 kV.
  • Work in low induction
  • Active part located in the inner enclosure of the transformer.
  • Fine graduation nozzle.
  • Stainless steel expansion bellows
  • With open delta winding and damping unit, ferro-resonance can be minimized.
  • Large secondary terminal box.

Type

  • EOF (24 -245) kV Outdoor Use, insulated in Paper - Oil
  • EGF (245 - 550) kV Outdoor Use, insulated in SF6 Gas

More information: www.pfiffner-group.com

Capacitive Voltage Transformers for Outdoor Use

Voltage transformers are used in high-voltage networks in the range 24 - 550 kV. They transform high voltage into standardized values for meters and protection and measuring devices.

Technical Characteristics:

  • Insulation Paper -Oil
  • From 72 to 550 kV.
  • Ferro-resonance free.
  • Carrier Wave Coupling Capacitor (PLC)...
  • Protected against sudden transient overvoltage surges on the high side

Type

  • ECF (72 - 550) kV Outdoor Use, Insulated in Paper - Oil
  • ROF (72 - 550) kV Resistive Divider Outdoor Use, Pape Insulated - Oil

More information: www.pfiffner-group.com

Combined transformers for outdoor use

Combined current and voltage transformers are used in high-voltage networks in the 245 -550 kV range. They transform high voltage into standardized values for meters and protection and measuring devices.

Technical Characteristics:

  • SF6 gas insulation.
  • From 24 to 550 kV.
  • It combines all the advantages of current and voltage transformers.
  • Guaranteed accuracy throughout the service life.
  • Reduced transportation and installation costs.
  • Requires less space for installation.

Type

  • EJOF (24 - 170) kV Outdoor Use, Insulated in Paper - Oil
  • EJGF (245 - 550) kV Outdoor Use, Insulated in SF6

More information: www.pfiffner-group.com