COURSES

THEORETICAL AND PRACTICAL

We offer theoretical and practical courses for engineers and electrical technicians on electrical concepts and testing.

SERVICE OF

LABORATORY

We have a complete laboratory for calibration and repair of test instruments with which we provide after-sales support.

CRIMPER

Satellite Controlled Clock for Substation REFERENCE: EM4278-C- Model 1094B

TECHNICAL CHARACTERISTICS: 

Yellow insulated eyelet terminal, electrolytic copper/pvc anti-flame. 0,25 - 160mm.

REFERENCE: AN2421-C

TECHNICAL CHARACTERISTICS: 

Insulated eyelet terminal, red insulation color, electrolytic copper/pvc anti-flame. 0,25 - 160mm working temp. -40°c Max 90°c.

REFERENCE: AN2435-C

TECHNICAL CHARACTERISTICS: 

Insulated eyelet terminal, blue insulation color, electrolytic copper/pvc rigid flameproof. 1,30 - 260mm, working temp. -40°c Max 90°c.

PART NUMBER: AN2450

TECHNICAL CHARACTERISTICS

Insulated eyelet terminal M5 color yellow insulation, electrolytic copper/pvc rigid anti-flame. 2,60 - 6,60mm, (12 to 10 AWG) working temp. -40°c Max 90°c.

PART NUMBER: CT3905

TECHNICAL CHARACTERISTICS

Insulated Tubular ferrules for 2 cables - DIN Standard, 0.75 mm², INSULATION COLOR: Gray.

PART NUMBER: CT3908

TECHNICAL CHARACTERISTICS

Insulated Tubular ferrules for 2 cables - DIN Standard,2,50 mm², INSULATION COLOR: Blue.

PART NUMBER: CT3909

TECHNICAL CHARACTERISTICS

Insulated Tubular ferrules for 2 cables - DIN Standard,4,00 mm², INSULATION COLOR: Gray.

REFERENCE: EF4213

TECHNICAL CHARACTERISTICS

Insulated Female, 0.25 to 1.00 mm² (22 to 18 AWG), INSULATION COLOR: Red, TERMINAL RAW MATERIAL : Brass, WORKING TEMPERATURE : Minimum -40 Cº and Maximum 90º C.

REFERENCE: EM4278-C

TECHNICAL CHARACTERISTICS

Male type coupler.

SECTION: from 1.30 to 2.60 mm² (16 to 14 AWG), INSULATION COLOR: Blue, Electrolytic Copper, INSULATION RAW MATERIAL: Rigid PVC anti-flame WORKING TEMPERATURE: Minimum of -40 Cº and Maximum of 90º C.

PART NUMBER: AN2420-C

TECHNICAL CHARACTERISTICS

Yellow insulated eyelet terminal, electrolytic copper/pvc anti-flame. 0,25 - 160mm.

REFERENCE: AT7217

TECHNICAL CHARACTERISTICS

Compression Tubular Terminal, M6 (1 hole / 1 compression), 10 mm², : Electrolytic Copper.

ELECTRICAL CONDUCTIVITY: About 96.6% IACS.

SURFACE TREATMENT: Electrolytically tinned.

WORKING TEMPERATURE: Maximum 149º C.

REFERENCE: AT7223

TECHNICAL CHARACTERISTICS

Compression Tubular Terminal, M6 (1 hole / 1 compression), 16 mm², Electrolytic Copper, Electrolytically tinned, OPERATING TEMPERATURE: Maximum 149º C.

PART NUMBER: CT3804

TECHNICAL CHARACTERISTICS

Single Insulated Tubular Insulated Terminals, 0.50 mm electrolytically tinned, Insulation Color - white, Working Temperature -54 °C max. 105°C.

PART NUMBER: CT3807

TECHNICAL CHARACTERISTICS

Single Insulated Tubular Insulated Terminations, 1.50 mm, electrolytically tinned, Insulation Color - black, Working Temperature -54 °C max. 105°C.

PART NUMBER: CT3808

TECHNICAL CHARACTERISTICS

Single Insulated Tubular ferrules, 2.50 mm, electrolytically tinned, Insulation color - blue, Working temperature -54 °C max. 105°C.

PART NUMBER: CT3810

TECHNICAL CHARACTERISTICS

Single Insulated Tubular Insulated Terminations, 6.00 mm, electrolytically tinned, Insulation Color - yellow, Working Temperature -54 °C max. 105°C.

PART NUMBER: CT3906

TECHNICAL CHARACTERISTICS

Insulated Tubular ferrules for 2 cables - DIN Standard, 1.00 mm², INSULATION COLOR: Red.

PART NUMBER: CT3907

TECHNICAL CHARACTERISTICS

Insulated Tubular ferrules for 2 cables - DIN Standard, 1.50 mm², INSULATION COLOR: Black.

PART NUMBER: FR2462-C

TECHNICAL CHARACTERISTICS

Insulated fork terminals, M3, from 0.25 to 1.60 mm² (22 to 16 AWG).

INSULATION COLORRed, Electrolytic Copper.

SURFACE TREATMENTTin-plated.

PART NUMBER: FR2479-C

TECHNICAL CHARACTERISTICS

Insulated fork terminals, M4, from 1.30 to 2.60 mm² (16 to 14 AWG).

INSULATION COLOR: Blue, Electrolytic Copper, Electrolytically tinned.

WORKING TEMPERATURE: Maximum 149º C.

REFERENCE: NA4501

TECHNICAL CHARACTERISTICS

Nylon couplings (female), from 0.25 to 1.00 mm² (22 to 18 AWG).

INSULATION COLOR: Red, Brass, Electrolytically tinned.

WORKING TEMPERATURE: Maximum 149º C.

REFERENCE: NA4503

TECHNICAL CHARACTERISTICS

Nylon couplings (female), from 1.10 to 2.60 mm² (16 to 14 AWG).

INSULATION COLOR: Blue, Brass, Electrolytically tinned.

WORKING TEMPERATURE: Maximum 149º C.

REFERENCE: NA4511

TECHNICAL CHARACTERISTICS

Nylon couplings (male), from 0.25 to 1.60 mm² (22 to 16 AWG).

INSULATION COLORElectrolytic copper, electrolytically tinned.

WORKING TEMPERATURE: Maximum 149º C.

REFERENCE: NA4513

TECHNICAL CHARACTERISTICS

Nylon couplings (male), from 1.30 to 2.60 mm² (16 to 14 AWG).

INSULATION COLOR: Blue, Electrolytic Copper, Electrolytically tinned.

WORKING TEMPERATURE: Maximum 149º C.