Current and Potential Transformers

Current Transformers for Outdoor Use

Current transformers are used in high-voltage networks in the range of 24 -550 kV. They transform high currents to standardized values for meters and protection and measuring devices.

Technical Characteristics:

  • Paper-Oil and SF6 Gas Insulation.
  • From 24 to 550 kV.
  • Minimal oil volume, high grade mineral oil and PCB-free.Instrument transformers (CT/PT)
  • The active part is located in the transformer head enclosure.
  • Fine graduation nozzle.
  • Stainless steel expansion bellows
  • Ratio change through primary (optional Secondary).
  • Housing explosion tested.
  • Precise control of the electric field and prevention of local partial discharges through the fine graduated nozzle.
  • Increased safety by preventing subsequent arching formation.
  • High operational safety, as there are no live parts in the isolator.

Type

  • JOF T (24 -123) kV Outdoor Use, insulated in Paper - Oil
  • JOF (24 - 550) kV Outdoor Use, insulated in Paper - Oil
  • JGF (245 - 550) kV Outdoor use, insulated in SF6 Gas

More information: www.pfiffner-group.com

Inductive Voltage Transformers for Outdoor Use:

Voltage transformers are used in high-voltage networks in the range 24 - 550 kV. They transform high voltage into standardized values for meters and protection and measuring devices.

Technical Characteristics:

  • Paper-Oil and SF6 Gas Insulation.
  • From 24 to 550 kV.
  • Work in low induction
  • Active part located in the inner enclosure of the transformer.
  • Fine graduation nozzle.
  • Stainless steel expansion bellows
  • With open delta winding and damping unit, ferro-resonance can be minimized.
  • Large secondary terminal box.

Type

  • EOF (24 -245) kV Outdoor Use, insulated in Paper - Oil
  • EGF (245 - 550) kV Outdoor use, insulated in SF6 Gas

More information: www.pfiffner-group.com

Capacitive Voltage Transformers for Outdoor Use

Voltage transformers are used in high-voltage networks in the range 24 - 550 kV. They transform high voltage into standardized values for meters and protection and measuring devices.

Technical Characteristics:

  • Insulation Paper -Oil
  • From 72 to 550 kV.
  • Ferro-resonance free.
  • Carrier Wave Coupling Capacitor (PLC)...
  • Protected against sudden transient overvoltage surges on the high side

Type

  • ECF (72 - 550) kV Outdoor Use, Insulated in Paper - Oil
  • ROF (72 - 550) kV Resistive Divider Outdoor Use, Pape Insulated - Oil

More information: www.pfiffner-group.com

Combined transformers for outdoor use

Combined current and voltage transformers are used in high-voltage networks in the range 245 -550 kV. They transform high voltage into standardized values for meters and protection and measuring devices.

Technical Characteristics:

  • SF6 gas insulation.
  • From 24 to 550 kV.
  • It combines all the advantages of current and voltage transformers.
  • Guaranteed accuracy throughout the service life.
  • Reduced transportation and installation costs.
  • Requires less space for installation.

Type

  • EJOF (24 - 170) kV Outdoor Use, Insulated in Paper - Oil
  • EJGF (245 - 550) kV Outdoor Use, Insulated in SF6

More information: www.pfiffner-group.com